WPI/Oxygen Sensor/normal/VAR-7803
产品编号:VAR-7803
市  场 价:¥100240.00
场      地:美国(厂家直采)
产品分类: 蛋白类>多肽>多肽合成>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:$5012.00
品      牌: wpiinc
公      司:WPI
公司分类:
WPI/Oxygen Sensor/normal/VAR-7803
商品介绍
Overview

Detect O2 for real-time analysis

  • Fluorescence-sensing detector for optical sensors, a viable alternative to traditional chemical sensing devices
  • Measure fluorescence lifetime, phase and intensity
  • LED based photometry makes this unit affordable–Half the cost of comparable phase measurement systems
  • Excellent stability, extremely low drift and phase noise
  • Simple calibration, setup and control
  • Oxygen Monitoring Kit, including:
    • Phase measurement system
    • Temperature probe 
    • Select sensor patches when ordering
Details

Options

Order codeDescription
FLOX-PATCHNon-Invasive Oxygen Monitoring Kit, including phase measurement system, temperature probe; select sensor patches when ordering
FLOX-PROBEIn Situ Oxygen Monitoring Kit, including phase measurement system, temperature probe; select sensor when ordering

Benefits

  • Self-contained, benchtop system–invariant to fiber bending or stray light
  • Easy setup and control, combined with its stability and sensitivity make this unit perfect for long term studies
  • Three coatings for probes and patches give you many options

Applications

  • Oxygen sensing applications requiring stability and sensitivity to drift which must be undisturbed for lengths of time
  • Monitor O₂partial pressure in gas and aqueous solutions and in non-aqueous vapors and solutionsMonitor traces of oxygen in gas and liquids

FLOX is a device for measuring fluorescence lifetime, phase and intensity. It uses LED excitation and photodiode detection with filter-based wavelength selection for easy experimental set-up and control.

Self contained unit

The compact, self-contained unit makes it invariant to fiber bending and stray light. It also has a wide dynamic range of optical intensity, as well as low optical and electronic crosstalk, and low drift and phase noise.

FLOX is especially useful for oxygen sensing applications where stability and sensitivity to drift is important and where sample set-ups must be left undisturbed for long periods of time.

Easy setup, great for long term studies

The new oxygen sensing system measures fluorescence lifetime, phase and intensity, using LED excitation and photodiode detection with filter-based wavelength selection. The system is simple to set-up and control. When stability and sensitivity to drift are important in your oxygen sensing experiment, this unit is ideal. It is perfect for applications where sample set-ups must be left undisturbed for long periods of time.

Three coatings available for probes and patches

The optical sensors consist of transducer materials, applied to the tips of optical fibers or to substrates such as patches or cuvettes, which change optical properties in response to specific analytes in their immediate environment.

OXY–The standard oxygen sensor designed for monitoring oxygen partial pressure in gas and aqueous solutions is a fiber optic fluorescence probe with a proprietary oxygen sensing coated tip.

HIOXY–Designed for monitoring oxygen partial pressure in non-aqueous vapors and solutions. The sensor coating chemistry is compatible with oils, alcohols, and hydrocarbon-based vapors and liquids.

FOSPOR–A new generation of highly sensitive sensor coating can be used for monitoring traces of oxygen in gas and liquids.

The oxygen sensor probes are low-power and offer high sensitivity, reversibility and stability, ideal for remote monitoring. The thin coating on the probe tips consumes no oxygen, allowing for continuous contact with the sample. They are ideal for viscous samples and are immune to interference caused by pH, ionic strength or salinity fluctuations or biofouling.

FLOX software displays oxygen measurements on a connected PC.

Specifications
Probe SpecificationsOXY Formulation (general-purpose coating)FOSPOR Formulation (high-sensitivity for low levels of O2)HIOXY Formulation (for hydrocarbon environments)
O2% range (at 1 ATM)0-100%0-<10%0-20.9%
DO range (ppm at 1 ATM)0-40 ppm0-4 ppm0-8 ppm
Temperature range-50-+80ºC for probes0-+60ºC for probes-50-+60ºC
0-60 ºC for patches0-60ºC for patchesNA 
O2% resolution100 ppm in gas10 ppm in gas100 ppm
DO resolution (at room temp)4 ppb0.4 ppb4 ppb
O2% accuracy<5% of reading<5% of reading<5% of reading
DO accuracy<5% of reading<5% of reading<5% of reading
Min. detectable level in gas0.01% - 0.05%0.001% - 0.01%0.01% - 0.05%
Response time (in gas)< 1 second< 30-60 second< 1 second
Response time w/ overcoating in gas45-60 seconds60-90 seconds 
Response time in pure water30-45 seconds60-90 seconds~45 seconds

 

Patch SpecificationsOXY Formulation (general-purpose coating)FOSPOR Formulation (high-sensitivity for low levels of O2)HIOXY Formulation (for hydrocarbon environments)
O2% range (at 1 ATM)0-100%0-10%0-20%
DO range (ppm at 1 ATM)  0-40 ppm0-4 ppm0-8 ppm
Temperature range-20 to +60 ºC for patches0 to +60 ºC for patches-20 to +60 ºC for patches
O2% resolution (20 sec averaging)0.05%0.01% 
 (at 30 sec averaging)0.05%  
DO resolution (at room temp)20 ppb4 ppb20 ppb
O2% accuracy5% of reading5% of reading5% of reading
DO accuracy5% of reading5% of reading5% of reading
Min. detectable level 0.1% O20.01% O2 
  (at 30 sec averaging)0.1% O2  
Minimum detectable level in water (room temperature)40 ppb    4 ppb40 ppb
Response time (in gas)<1 second30-60 seconds<1 second

Response time w/ overcoating in gas

~30-45 seconds~60-90 seconds 
Response time in pure water~45 seconds~60-90seconds~30-45 seconds

 

Stability (Continuous LED)OXY Formulation (general-purpose coating)FOSPOR Formulation (high-sensitivity for low levels of O2)HIOXY Formulation (for hydrocarbon environments)
Lifetime Stability (Tau)0.0006 usec/ HR0.003 usec/ HR0.0002 usec/HR
Oxygen Stability %0.01% HR0.005% HR0.007% HR

 

Sterilization GuideOXY Formulation (general-purpose coating)FOSPOR Formulation (high-sensitivity for low levels of O2)HIOXY Formulation (for hydrocarbon environments)
Form factorProbes/PatchesProbes/PatchesProbes
AutoclavableNoNot yet determinedYes
Calibration  Single point reset required after sterilization
GammaYesNot yet determinedYes

Options Also Available

AL300A 500 µm OD (300 µm core diameter) aluminum-jacketed optical fiber probe for applications that require fine spatial resolution. 300 µm alµminµm-jacketed fiber assembly; 500 µm OD, 1 m length
OR125The OR125 is a 1/8" OD optical fiber probe used as a direct replacement for 1/8" OD O2 electrodes.100 µm optical fiber, stainless steel ferrule; 3.175 mm OD, 63.5 mm length
P1600The PI600 is a silicone-jacketed, polyimide-coated optical fiber probe used in environments where a non-metallic probe is required.200 or 600 µm optical fiber with silicone jacketing; 710 µm OD, 2 m length
OR125G and OR125GTThese probes are 1/8" OD optical fiber probes used as direct replacement for 1/8" OD O2 electrodes.1000 µm optical fiber, stainless steel ferrule; 3.175 mm OD, 63.5 mm length
R Sensor Probe1000 µm fiber in a stainless steel 1/16" ferrule; 1.587 mm OD, 152.4 mm length
Reviews
品牌介绍

WPI(World Precision Instruments Inc.)公司的使命是给神经生理学、心血管生理学和细胞生物学等广大 生物医学科研工作者提供研究用的仪器和工具,使其研究更完善,更**,更精确。WPI China将秉承WPI的理念为中国大陆,中国香港和台湾地区科学 研究者提供优质的产品和周到的服务。

 近年来,WPI产品线由神经电生理产品逐渐延伸到生物感应器,心血管生理、病理和心血管药理,光谱检测等领域,革新的产品包括:

WPI-TBR1025/4100, 一氧化氮、硫化氢和过氧化氢等自由基检测仪为全球**和行业领导供应商。

EVOM2, 一款可以在6孔、12孔、24孔和96孔培养板中进行跨膜电阻测量的跨膜电阻仪,是该领域的产品风向标,用于上皮、内皮和肿瘤细胞培养过程中细胞状态的检测,并常用于药物动力学研究和肿瘤药效检测。

WPI-LWCC, 世界上**可以将光程做到2米以上微量样本检测流通池的生产厂家,可以用于海洋微量元素和环境微量物质的检测。

微量注射系统:PV系列气动微量注射系统用于质粒转染和细胞内注射;纳升微量注射系统可以确保您注射的精确到纳升级;多款微注射系统任您选择。

        WPI的历史超过40年,在美国、英国、德国、加拿大、澳大利亚、新西兰、法国等欧美生物医学实验室是****的领导供应商之一,供应实验室产品种类超过5000种。我们也将为国内的科学家提供包含神经电生理、生物感应器、心血管和光谱等成套设备的销售及服务,同时提供数据采集系统 、动物实验等手术器械和玻璃毛细管等耗材的销售及服务。


自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔